Restart 36, 7 restart – Pilz PSSnet SHL 8T MRP User Manual
Page 36
Basic Settings
36
1.7 Restart
PSSnet SHL - Web- based Interface
Pilz GmbH & Co. KG, Felix- Wankel Str. 2, 73760 Ostfildern
1.7 Restart
With this dialog you can:
X
Cold start the device. In a cold start, the device reloads the software from
the non-volatile memory, restarts, and performs a self-test.
X
Warm start the device. In this case the device checks the software in the
volatile memory and restarts.
X
Reset the entries with the status "learned" in the filter table (MAC address
table),
X
Reset the ARP table (the device maintains an ARP table internally. If, for
example, you assign a new IP address to a computer and subsequently
have problems with the connection, you then reset the ARP table).
X
Reset the port counters,
X
Delete the log file.
Note: During the restart, the device temporarily does not transfer any data,
and it cannot be accessed via the Web-based interface or other management
systems such as HiVision.