LON 100 Internet Server Programmer’s Reference
Function Names
Description
DataloggerList
DataloggerGet
DataloggerSet
DataLoggerRead
DataLoggerClear
DataloggerDelete
Use the DataLoggerList function to return the index number, last update time,
description, and functional block name of each Data Logger that you have added
to the
i.
LON 100. You can use the DataLoggerGet function to return the
configuration of any of these Data Loggers.
Use the DataLoggerSet function to add new Data Loggers to the
i.
LON 100, or to
overwrite the configuration of existing Data Loggers. Use the DataLoggerDelete
function to remove Data Loggers from the
i.
LON 100.
Use the DataLoggerRead function to read data from the log files generated by
your Data Loggers. Use the DataLoggerClear function to remove data from the
log files.
For more information on these functions, see Data Loggers on page 6-1.
AlarmGeneratorList
AlarmGeneratorGet
AlarmGeneratorSet
AlarmGeneratorDelete
Use the AlarmGeneratorList function to return the index number, last update
time, description, and functional block name of each Alarm Generator that you
have added to the
i.
LON 100. You can use the AlarmGeneratorGet function to
return the configuration of any of these Alarm Generators.
Use the AlarmGeneratorSet function to add new Alarm Generators to the
i.
LON
100, or to overwrite the configuration of existing Alarm Generators. Use the
AlarmGeneratorDelete function to remove Alarm Generators from the
i.
LON
100.
For more information on these functions, see Alarm Generator on page 7-1.
AlarmNotifierList
AlarmNotifierGet
AlarmNotifierSet
AlarmNotifierDelete
AlarmNotifierRead
AlarmNotifierWrite
AlarmNotifierClear
Use the AlarmNotifierList function to return the index number, last update
time, description, and functional block name of each Alarm Notifier that you
have added to the
i.
LON 100. You can use the AlarmNotifierGet function to
return the configuration of any of these Alarm Notifiers.
Use the AlarmNotifierSet function to add new Alarm Notifiers to the
i.
LON 100,
or to overwrite the configuration of existing Alarm Notifiers. Use the
AlarmNotifierDelete function to remove Alarm Notifiers from the
i.
LON 100.
Use the AlarmNotifierRead function to read the log files generated by your
Alarm Notifiers. Use the AlarmNotifierWrite function to comment on and
acknowledge the entries in the log files. Use the Alarm NotifierClear function to
remove entries from the log files.
For more information on these functions, see Alarm Notifier on page 8-1.
AnalogFBList
AnalogFBGet
AnalogFBSet
AnalogFBDelete
Use the AnalogFBList function to return the index number, last update time,
description, and functional block name of each Analog Function Block that you
have added to the
i.
LON 100. You can use the AnalogFBGet function to return
the configuration of any of these Analog Function Blocks.
Use the AnalogFBSet function to add new Analog Function Blocks to the
i.
LON
100, or to overwrite the configuration of existing Analog Function Blocks. Use
the AnalogFBDelete function to remove Analog Function Blocks from the
i.
LON
100.
For more information on these functions, see Analog Function Block on page 9-1