Jt60/jt60 all terrain operator’s manual – Ditch Witch JT60AT User Manual
Page 179

JT60/JT60 All Terrain Operator’s Manual
Service - 179
Startup/10 Hour
Test Control Switches
Test control proximity switches every 10 hours.
To test:
1.
Turn ignition switch to the on position. Do not start engine.
2.
Place metal object above target on each switch.
3.
If yellow LED on switch lights, switch sensor is working.
Check Pipe Auto Lubricator Spray
Nozzle
Check pipe auto lubricator spray nozzle before
startup and every 10 hours of operation. Ensure
that nozzle is free of obstructions and operates
properly. Clean as needed.
To clean:
1.
Rotate handle to the upward, or clean out, position (A).
2.
Operate pump until obstruction is flushed.
3.
Rotate handle to the downward, or spray, position (B).
4.
Clean nozzle guard. If necessary, pull handle/nozzle insert out of housing to clean with fine wire or
solvent.
1. Drive position switch
2. Drill position switch
3. Rear stop switch
4. Rear home switch
5. Shuttle home switch
6. Front home switch
NOTICE: Ditch Witch tool joint compound is
specially formulated to work with Ditch Witch
pipe lubrication system. Use of other tool joint
compounds will clog system. See
“Recommended Lubricants/Service Key” on
page 170 for more information.
j40om027w.eps
j40om029w.eps