Startup/10 Hour
Check Hydraulic Fluid Level
Check hydraulic fluid level before startup and
every 10 hours of operation. Maintain fluid level at
halfway point on sight glass (1), when engine is
off and fluid is cool. Refill with THF at hydraulic
fluid fill (2).
Check Fluid Pump Oil Level
Check fluid pump oil level at sight glass or
petcock (2) before startup and every 10 hours of
operation. Maintain fluid level at halfway point on
sight glass or at petcock level. Fill at cap (1) with
TF30.
IMPORTANT: If hydraulic system must be
opened for repair, install new filter (p/n 157-
486) for first 50 hours of operation. If this filter
becomes plugged in fewer than 20 hours,
replace with clean filter. After 50 hours of
normal operation, replace with clean filter.