Prepare - 64

JT60/JT60 All Terrain Operator’s Manual

Classify Jobsite

Classify Jobsite

Inspect Jobsite

Follow U.S. Department of Labor regulations on excavating and trenching (Part 1926, Subpart P) and
other similar regulations.

Contact your local One-Call (811 in USA) or the One-Call referral number (888-258-0808 in USA and
Canada) to have underground utilities located before digging. Also contact any utilities that do not
participate in the One-Call service.

Inspect jobsite and perimeter for evidence of underground hazards, such as:

– “buried utility” notices

– utility facilities without overhead lines

– gas or water meters

– junction boxes

– drop boxes

– light poles

– manhole covers

– sunken ground

Have an experienced locating equipment operator sweep area within 20’ (6 m) to each side of bore
path. Verify previously marked line and cable locations.

Mark location of all buried utilities and obstructions.

Classify jobsite.

Select a Classification

Jobsites are classified according to underground hazards present.

If working . . .

then classify jobsite as . . .

within 10’ (3 m) of a buried electric line

electric

within 10’ (3 m) of a natural gas line

natural gas

in sand, granite, or concrete which is capable of producing
crystalline silica (quartz) dust

crystalline silica (quartz) dust

within 10’ (3 m) of any other hazard

other

IMPORTANT: If you have any doubt about jobsite classification, or if jobsite might contain unmarked
hazards, take steps outlined previously to identify hazards and classify jobsite before working.