ADLINK PCI-8154 User Manual
Page 200

190
Function Library
B_8154_get_error_counter(ByVal AxisNo As Integer,
ByRef error As Integer) As Integer
B_8154_reset_error_counter(ByVal AxisNo As
Integer) As Integer
B_8154_set_general_counter(ByVal AxisNo As
Integer, ByVal CntSrc As Integer, ByVal
CntValue As Double) As Integer
B_8154_get_general_counter(ByVal AxisNo As
Integer, ByRef Pos As Double) As Integer
B_8154_reset_target_pos(ByVal AxisNo As Integer,
ByVal Pos As Double) As Integer
B_8154_get_target_pos(ByVal AxisNo As Integer,
ByRef Pos As Double) As Integer
B_8154_set_res_distance(ByVal AxisNo As Integer,
ByVal Res_Distance As Double) As Integer
B_8154_get_res_distance(ByVal AxisNo As Integer,
ByRef Res_Distance As Double) As Integer
@ Argument
AxisNo
: Axis number designated to move or stop.
Pos
, *Pos: Feedback position counter value, (_8154_get/
set_position)
range: -134217728 to 134217727
Cmd
, *Cmd: Command position counter value,
range: -134217728 to 134217727
*error
: Position error counter value,
range: -32768 to 32767
card_id Physical axis AxisNo
0
0
0
1
1
2
2
3
3
1
0
4
1
5
…
…