BTH S E R V I C E H A N D B O O K

N S T A L L A T I O N

EXTERIOR SIDEWALL CLEARANCES

Horizontal Vent (Using Room Air for Combustion)

When multiple units are directly vented through a wall, all intake vent terminals must be no lower
than the highest exhaust vent terminal.

CAUTION DO NOT TERMINATE THE VENTING WHERE NOISE FROM THE EX­

HAUST OF INTAKE WILL BE OBJECTIONABLE. THIS INCLUDES LOCATION CLOSE TO

OR ACROSS FROM WINDOWS AND DOORS. AVOID ANCHORING THE VENT AND

INTAKE PIPES DIRECTLY TO FRAMED WALLS, FLOORS OR CEILINGS UNLESS RUB­
BER ISOLATION PIPE HANGERS ARE USED. THIS PREVENTS ANY VIBRATIONS
FROM BEING TRANSMITTED INTO THE LIVING SPACES.