beautypg.com

Component information, Orifice table – A.O. Smith 960 through 967 User Manual

Page 35

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

background image

BTH S E R V I C E H A N D B O O K

C O M P O N E N T I N F O R M A T I O N

COMPONENT INFORMATION

FLAME SENSING ROD

AOS PART NUMBER

FLAME SENSING CURRENT

COMMENTS

192478

0.7 Micro Amp (p)

BTH 120-250

HOT SURFACE IGNITOR (HSI)

AOS PART NUMBER

VOLTAGE

AMP

OHMS COLD

COMMENTS

192638

120 VAC

1.0

50 - 300

BTH 120-250

ORIFICE TABLE

ORIFICE TABLE

BTH MODEL

MAIN BURNER

ORIFICE NO.

MAIN ORIFICE SIZE

INCHES

AIR ORIFICES

PT. NO.

AIR ORIFICE

SIZE — INCHES

120

192477-3

0.204

192450-3

0.788

150

192477-1

0.235

192450-1

0.875

199

192477-0

0.304

192450-0

1.031

250

192477-2

0.360

192450-2

1.196

120 Prop

192477-6

0.125”

192450-5**

0.872

150 Prop

192477-5

0.141”

192450-5**

0.872

199 Prop

192477-4

0.166”

192450-4**

1.150

*-4 and -5 Red plated for Propane.

** -4 and -5 stamped with “P” for Propane

N O T E :

Hex head of main burner orifice is upstream end — gas flows out of tapered end.