BTH S E R V I C E H A N D B O O K
T R O U B L E S H O O T I N G
IGNITOR RESISTANCE
STEP 11
IGNITOR RESISTANCE CHECK
■
f
CN6 CN1 CN2
STEP 11: CHECK RESISTANCE BETWEEN TWO WIRE CONNECTS AT CN5 IGNITOR PLUG
END.
Condition:
• On/Off switch is off.
• Disconnect CN5 ignitor plug from circuit board.
• Multimeter is set to lowest ohms scale above 300 ohms.
IF...
THEN
ohms reading taken is not between 50 - 300 ohms
replace the ignitor.
ohms reading taken is between 50 - 300 ohms
reconnect CN5 plug, continue to Step 12.