beautypg.com

Gas pressure check, Manifold gas pressure test – A.O. Smith 960 through 967 User Manual

Page 34

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

background image

BTH S E R V I C E H A N D B O O K

T R O U B L E S H O O T I N G

GAS PRESSURE CHECK

Attach manometer or gas pressure gauge to pressure tap on gas valve or use adapter to check

pressure ahead of valve as near as possible to valve. All appliances being served by this gas sup­
ply line should be operating.

IF...

THEN

supply gas pressure is not between 5.0 and 14” W.C.
natural gas or 11.0 and 14” W.C. propane

adjust supply gas pressure (Recommended supply
minimum is 7.0” W.C. for natural gas models)

proper supply gas pressure is present

continue to Step 14.

STEP 14

MANIFOLD GAS PRESSURE TEST

STEP 14: CHECK AND ADJUST MANIFOLD GAS PRESSURE.

IF...

THEN

manifold gas pressure is not:

natural gas models

3.5” W.C. ± 0.3” - BTH 155 & 199

4.0” W.C. ± 0.3” - BTH 120 & 250

propane gas models

10.0” W.C. ± 0.3” - all propane gas models.

adjust manifold gas pressure to values given for model
and fuel type (within 0.3” W.C. tolerance)

if manifold gas pressure cannot be adjusted to
maintain values given (within 0.3” W.C. tolerance)
replace gas valve.

manifold gas pressure is within tolerances given above

ignition should occur.

A. O. Smith Water Products Co.
Ashland City, Tennessee © 2004

33

Technical Training Department

TC-044 Revision 6