INSTALLATION
06D,07D
m
Table 1 - 07D Condensing Unit Data
C o n d e n s i n g U n i t
A 1 0 2
A 2 0 3
A 1 0 3
A 1 0 6
------------------------- 1
A 2 0 8
A .
2 1 0
B
A
' ^ 2 1 5
B
C o m p r e s s o r M o
l e i
0 6 D A 1 0 9
0 6 D A 8 0 8
0 6 D A 0 1 3
0 6 D A 7 1 8
0 6 D A 8 1 8
0 6 D A 7 2 4
0 6 D A 3 3 7
0 6 D A 5 3 7
U n i t T y p e
W C
W C
W C
W C
W C
W C
W C
W C
W C
N o m i n a l T o n s
2
3
3
5
5
7 - 1 / 2
1 0
1 0
1 5
E v a p T e m p L e \
e l
H , M , L
H , M
H , M
H
M
H , M
H , M
H , M
H , M
N o . o f C y 1 i n d e r s
2
2
4
4
4
4
6
6
6
B o r e o n d S t r o k e ( i n )
2 X 1 - 3 / 8
2 X 1 - 1 / 4
1 - 1 3 / 1 6 X 1 - 1 / 4
2 X 1 - 7 / 1 6
2 X 1 - 7 / 1 6
2 X 1 - 7 / 1 6
2 X 1 - 1 / 4
2 X 1 - 1 5 / 1 6
2 X 1 - 1 5 / 1 6
C o m p r S p e e d ( r p m )
1 7 5 0
1 7 5 0
1 7 5 0
1 7 5 0
1 7 5 0
1 7 5 0
1 7 5 0
1 7 5 0
1 7 5 0
D i s p I a t 1 7 5 0 R p m ( c f m )
8 . 6 9
7 9 6
1 3 . 1
1 8 . 3
1 8 . 3
1 8 3
2 3 . 8 8
3 7 0 7
3 7 0 7
S u e t G a s C o n n
( O D F )
7 / 8
7 / 8
7 / 8
1 - 1 / 8
1 - 1 / 8
1 - 1 / 8
1 - 3 / 8
1 - 3 / 8
1 - 3 / 8
D i s c h G a s C o n n . ( O D F )
5 / 8
5 / 8
5 / 8
7 / 8
7 / 8
7 / 8
7 / 8
1 - 1 / 8
1 - 1 / 8
L i q L i n e C o n n
( O D F )
1 / 2
1 / 2
1 / 2
1 / 2
1 / 2
1 / 2
5 / 8
5 / 8
5 / 8
R e f r i g e r a n t
1 2
2 2
1 2
1 2
2 2
2 2
2 2
1 2
2 2
O p t g R e f C h a r g e ( l b s ) * *
2
2 . 5
2 . 7
2 . 0
1 . 9
2 7
3 . 2
4 . 3
4 . 3
C o n d S t o r o g e C a p
( 8 0 % L i q u i d a t 1 0 0 F )
1 8
1 8 . 5
2 0 . 5
3 9 . 5
3 5 . 8
4 5
6 7
8 8
8 8
W a t e r C o n n
I n l e t
1 / 2 F P T
1 / 2 F P T ( 2 )
1 / 2 F P T ( 2 )
1 / 2 F P T ( 2 )
1 / 2 F P T ( 2 )
3 / 4 F P T ( 2 )
1 - 1 / 2 M P T
* 1 - 1 / 2 F P T ( 2 )
* 1 - 1 / 2 F P T ( 2 )
C o o l i n g T o w e r
O u t l e t
1 / 2 F P T
3 / 4 M P T
3 / 4 M P T
1 M P T
1 M P T
1 M P T
* 1 - 1 / 2 M P T
2 F P T
2 F P T
W a t e r C o n n
I n l e t
1 / 2 F P T
1 / 2 F P T
1 / 2 F P T
1 / 2 F P T
1 / 2 F P T
3 / 4 F P T
1 - 1 / 2 M P T
1 - 1 / 2 F P T
1 - 1 / 2 F P T
C i t y W a t e r
O u t l e t
1 / 2 F P T
1 / 2 F P T
1 / 2 F P T
1 / 2 F P T
1 / 2 F P T
3 / 4 F P T
1 - 1 / 2 M P T
1 - 1 / 2 F P T
1 - 1 / 2 F P T
F r a n g i b l e D i s c s , M . F l .
3 / 8
3 / 8
3 / 8
3 / 8
3 / 8
3 / 8
3 / 8
3 / 8
3 / 8
* R e m o v e u p p e r h e a d e r p l u g f o r p a r a l l e l c i r c u i t i n g f o r c o o l i n g t o w e r a p p l i c a t i o n ( S e e F i g . 1 8 )
* * C o n d e n s i n g u n i t m i n i m u m o p e r a t i n g r e f r i g e r a n t c h a r g e
W C — W a t e r - C o o l e d
INSPECT THE SITE
Preliminary Survey
Before starting the installation, make a survey
to determine the following:
SPACE REQUIREMENTS
Dimensions for the 07D Condensing Units are
given in Table 2. Allow additional room to re
move the compressor heads and valve plates.
Place the unit so the suction and discharge shut
off valves can be easily reached and the oil
level checked.
Install the unit where it will be warmer than the
refrigerated space, to prevent refrigerant from
condensing in the compressor crankcase during
shutdown. Water-cooled condensing units must
be protected against freezing. Make provision
in the piping layout to drain and blow out the
condenser and water piping if the system is to
be shut down in winter.
Table 2 - Condensing Unit Dimensions
Unit
Length
(in.)
Width
(in.)
Height
(in.)
07DÂ102 WC 0 0)
21-3/8
12 ■
21-1/2
07DA102 WC (Poly 0)
29-1/16
12
21-1/2
07DA203 WC 0
29-1/2
12
21-7/16
07DA203 WC (Poly 0)
31-3/16
12
21-7/16
07DA103 WC (1
31-3/32
14
22-5/8
07DA103 WC (Poly0)
32-3/4
14
22-5/8
07DA106 WC (All)
33-1/4
14
27-7/8
07DA208 WC (All)
39-5/8
14
27-7/8
07DA210 WC (All)
39-11/16
15-1/2
31-7/32
07DA112 WC (All)
46-3/8
17-7/16
32-3/4
07DA215 WC (All)
46-3/8
17-7/16
32-3/4
NOTE: WC - Water-Cooled
13