beautypg.com

Engine run time -15 settings files -15 – Winco DGC-500 User Manual

Page 67

background image

DGC-500-500 BESTCOMS Software

4-13

Figure 4-16. Settings Screen, Output Setup Tab

Programmable Input - Alarm/Pre-Alarm. Either of these check boxes can be selected to annunciate an alarm
or pre-alarm when the selected function triggers the programmable input. Alarm or pre-alarm annunciation
is available only when one the following functions are selected: Auxiliary Input, Battery Charger Fail, Fuel Leak
Detect, or Low Coolant Level.

Programmable Input - Auxiliary Input Label. This setting field is active only when Auxiliary Input is selected
as the programmable input function. An user-assigned label (eight characters, maximum) can be entered for
the corresponding programmable input.

Output Setup Tab

The Output Setup Tab settings of the Settings screen are shown in Figure 4-16. (Not all settings are visible
in the illustration.) Each tab setting is described in the following paragraphs.

The Output Setup tab consists of a list of pre-alarms, alarms, and conditions that can be assigned to close
either Programmable Output 1 or 2. An output selected by clicking the checkbox in the appropriate row and
column. The following pre-alarms, alarms, and conditions can be assigned to one of the two programmable
outputs.

C

Battery Charger Failure Alarm

C

Battery Charger Failure Pre-alarm

C

Battery Overvoltage Pre-alarm

C

Coolant Temperature Sender Failure Alarm

C

Cooldown Timer Active

C

Emergency Stop Alarm

C

EPS Supplying Load

C

Fuel Leak Alarm

C

Fuel Leak Pre-alarm

C

Fuel Sender Failure Pre-alarm

C

High Coolant Temperature Pre-alarm

C

High Coolant Temperature Alarm

C

Loss of Voltage Sender Failure Alarm

C

Low Battery Voltage Pre-alarm

C

Low Coolant Level Pre-alarm

C

Low Coolant Level Alarm

C

Low Coolant Temperature Pre-alarm

C

Low Fuel Alarm

C

Low Fuel Pre-alarm

C

Low Oil Pressure Alarm

C

Low Oil Pressure Pre-alarm

C

Speed Sender Failure Alarm

C

Oil Pressure Sender Failure Alarm

C

Overcrank Alarm

C

Overspeed Alarm

C

Pre-start Condition in Effect

C

Programmable Input 1 Closed

C

Programmable Input 2 Closed

C

Programmable Input 3 Closed

C

Scheduled Maintenance Pre-alarm

C

Switch Not in Auto

C

Weak Battery Voltage Pre-alarm