9

6.2.2. Edit

Undo :

Cancels the previous operation and returns to the original state.

Repeat :

Repeats processing previously performed.

Cut :

Initializes the setting value after copying the setting value of the designated

box to the clipboard.

Copy :

Copies the setting value of the designated box to the clipboard.

Paste :

Pastes the clipboard data to the designated box.

Initial value :

Initializes the setting value of the box.

Set Grouping :

Performs the group setting of the box.

Release Grouping :

Cancels the group setting of the box.

Box Write Protect...

Off :

Sets no restriction on write to box.

Low :

Restricts the operator from changing the parameters set in the box.

Mid :

Restricts the operator from changing all settings in the box.

High :

Restricts the administrator from changing the parameters set in the box, and

the operator from changing all settings in the box.

6.2.3. View

Toolbar :

Shows or hides the toolbar.

Status Bar :

Shows or hides the status bar.

Unit View :

Shows or hides the unit view.

Contents View :

Shows or hides the contents view.

Response View :

Shows or hides the response view.

(See p. 34.)

Preset View

Show/hide :

Shows or hides the preset view.

Floating :

Floats the preset view window.

Docking :

Docks the preset view window.

Mute View

Show/hide :

Shows or hides the mute view.

(See p. 41.)

Floating :

Floats the mute view.

Docking :

Docks the mute view.

Level Monitor View :

Shows or hides the level monitor view.

(See p. 40.)

6.2.4. Unit

Create New Unit... :

Creates a new unit.

Click the flow view screen on the main screen to create the first unit.

Delete Unit :

Deletes the unit from the setting data.

Change X-over

Combination... :

Changes crossover combinations.

Slope... :

Changes crossover slopes.

Filter split :

Changes split settings of the output stage filter box.

Names... :

Changes the names of the unit and its inputs and outputs.

Save as a Template

Unit Template... :

Stores equipment configuration settings as a template.

X-over Template :

Stores crossover settings as a template.

Input PAD settings :

Changes the input sensitivity of the unit.

6.2.5. preset

Change

Preset 1 – 16 :

Recalls one out of 16 preset memories.

Store

Preset 1 – 16 :

Writes setting contents in one of 16 preset memories.

Names... :

Changes the name of preset memory.

Switching Host... :

Make settings to permit the unit’s Preset memory to be switched synchronously

when the Preset memory is switched at the M-864D or other DP-SP3 (Master