8.4.7. ATT view
If you click the
box in the signal flow, the ATT View is displayed.
(1)
(2)
(3)
(4)
(1) grouping button [grouping No.]
The group number is displayed when grouping has been set, and the “Off” indication is displayed when no
grouping has been set.
Clicking on this button permits grouping to be set or cancelled on the pull-down menu.
If you move a fader of a grouped channel up or down, the faders of other channels assigned the same group
also move in synchronization with the first operated fader.
(2) Fader
The signal level of each channel can be changed by moving the Fader up and down.
(3) level indication button [level (dB)]
Displays the signal level of each channel by means of numerical values.
If you click this button, a dialog for level setting is displayed, enabling
you to set the level by directly entering a numerical value.
(Setting range: -∞ - 0 dB)
The Up and Down buttons located on the right side can also be used to
change the value in 1 dB units.
(4) Mute button [Mute]
Click this button to determine whether (ON) or not (OFF) to use the mute function.
The ON/OFF status of the mute function for each channel is displayed on the Mute button.
Select either “New Group” or
the number of a group that has
already been set.
Only when “New Group” has been selected, select either “Same
Value” or “Keep Offset.”
Same Value: Makes gain value within the group identical.
Keep Offset: Permits gain values to be changed without
changing the relative gain values within the group
set at the time of group setting.