beautypg.com

See p. 20.) – Toa DP-SP3 User Manual

Page 20

background image

20

8.4.1. Matrix view

Clicking the Matrix box in the signal flow causes the Matrix view to be displayed.

• A circle mark in the matrix control column shows input/output routing.

• The Matrix control turns on and off as it is double-clicked.

• A black, thicker frame on the Matrix control shows the selected matrix point.

• The level at the selected matrix point can be changed by moving a fader up or down.

• The level at the selected matrix point is displayed numerically on the Level setting button. Pressing this button

permits direct entry by a numerical value.

You can also change the level in 1 dB units with the Up and Down buttons located on the right side.

• The level setting at each matrix point is displayed numerically by clicking the [Numerical] button.

Matrix control Fader

Numerical value indication button

Level setting button

Example of numerical display