Toa DP-SP3 User Manual
Page 24
![background image](/manuals/714318/24/background.png)
24
(4) Threshold button [Threshold (dB)]
Displays the compression threshold level for each channel by means of
numerical values.
The Up and Down buttons located on the right side can be used to change
the threshold level in 1 dB units.
Also, if you press this button, a dialog for threshold level setting is displayed
as shown at right, enabling you to set the level by directly entering a
numerical value.
(Setting range: –20 to +20 dB)
(5) Ratio button [Ratio]
Displays the compression ratio for each channel by means of numerical
values.
If this button is pressed, setting values can be selected from the pull-down
menu as shown at right.
The Up and Down buttons located on the right side can also be used to
change the value as shown at right.
(6) Sync button [Sync]
Sync for each channel is displayed on the Sync button.
If this button is clicked, selective input can be performed from the pull-down menu.
(7) Attach button [Attach Time (ms)]
Displays the compression attack time for each channel by means of numerical values.
Clicking this button permits setting values to be selected from the pull-down menu.
The Up and Down buttons located on the right side can also be used to change the value.
(8) Release button [Release Time (ms)]
Displays the compression release time for each channel by means of numerical values.
Clicking button permits setting values to be selected from the pull-down menu.
The Up and Down buttons located on the right side can also be used to change the value.