2.2.14 Printer Function Setting Commands

GS (D pL pH m [a1 b1] ··· [ak bk]

[Function]

Enabling or disabling real-time command

[Code]

<1d>H<28>H<44>pL pH m [a1 b1] ··· [ak bk]

[Range]

3 (pL + pH

× 256) 65535

m = 20

a = 1

b = 0, 1, 48, 49

[Default]

a

Kind of Real-time Command

Default

1

DLE DC4 fn m t(fn = 1): Real-time output of set pulse

Valid

[Outline]

Enables/disables the following real-time command processing.

a

b

Function

1

0, 48

Does not process DLE DC4 fn m t (fn = 1). (Invalid)

1, 49

Processes DLE DC4 fn m t (fn = 1). (Valid)

• pL and pH sets the number of bytes on and after m in (pL + pH

× 256).

• “a” sets the kind of real-time command.

• “b” sets Valid or Invalid.

When data raw that meets the code configuring real-time command in the image
data, it is recommended that the real-time command be set to Invalid by this