14 printer function setting commands, Gs (d pl ph m [a1 b1] ··· [ak bk – CITIZEN CT-S300 User Manual
Page 93

— 88 —
2.2.14 Printer Function Setting Commands
GS (D pL pH m [a1 b1] ··· [ak bk]
[Function]
Enabling or disabling real-time command
[Code]
<1d>H<28>H<44>pL pH m [a1 b1] ··· [ak bk]
[Range]
3 (pL + pH
× 256) 65535
m = 20
a = 1
b = 0, 1, 48, 49
[Default]
a
Kind of Real-time Command
Default
1
DLE DC4 fn m t(fn = 1): Real-time output of set pulse
Valid
[Outline]
Enables/disables the following real-time command processing.
a
b
Function
1
0, 48
Does not process DLE DC4 fn m t (fn = 1). (Invalid)
1, 49
Processes DLE DC4 fn m t (fn = 1). (Valid)
• pL and pH sets the number of bytes on and after m in (pL + pH
× 256).
• “a” sets the kind of real-time command.
• “b” sets Valid or Invalid.
When data raw that meets the code configuring real-time command in the image
data, it is recommended that the real-time command be set to Invalid by this
command.