Esc d [ n ] k null – CITIZEN CT-S300 User Manual
Page 38

— 33 —
ESC D [ n ] k NULL
[Function]
Setting horizontal tab position
[Code]
<1B>H<44>H [
[Range]
1 n 255
0 k 32
[Outline]
Specifying a horizontal tab position.
• “n” indicates the number of columns from the beginning to the horizontal tab
position. Note, however, that “n = set position – 1”. For example, to set the position
at 9th column, n = 8 is to be specified.
• “k” denotes the number of horizontal tab positions you want to set.
• The tab position is set at a position where it is “character width
× n” from the
beginning of a line. The character width, at this time, includes the space on the
right. In double width characters, it is made double the ordinary case.
• Tab positions that can be specified are maximum 32. Specifying tab positions
exceeding this limit is ignored.
•
<00> H.
• ESC D
tab command is ignored.
[Caution]
• When the data,
assumed that tab setting is finished. If this is the case, the next data onward will be
processed as normal data.
• When the data,
“Set column position = Maximum print columns + 1”.
• The horizontal tab position does not change even if the character width is altered
after setting the horizontal tab position.
[Default]
• At the selection of font A, tabs are set every 8 characters (at 9th, 17th, 25th, ...) with
right space amount of a character set at 0 and horizontal enlargement rate of a
character set at 1.
[See Also]
HT
[Sample Program]
Refer to Sample Program and Print Results for HT.