GS C2 n1 n2

[Function]

Setting the numbering counter

[Code]

<1D>H<43>H<32>H

[Range]

0 n1 255

0 n2 255

[Outline]

This command sets the numbering (serial number counter) value.

n1 + n2

× 256 (n1 = remainder, n2 = quotient) becomes a counter value.

[Caution]

• If the counter is set with this command, a repeat count of the idential count will be

cleared.

• If the counter value is beyond the range specified with the GS C1 or GS C; command,

the counter will be initialized.

[Default]

Not defined.

[See Also]

GS C0, GS C1, GS c, GS C;

[Sample Program]

[Print Results]