beautypg.com

Gs (m pl ph fn m fn = 3, 51 – CITIZEN CT-S300 User Manual

Page 120

background image

— 115 —

fn = 3, 51: Function 3

GS (M pL pH fn m fn = 3, 51

[Code]

<1d>H<28>H<4D>pL pH fn m

[Range]

(pL + pH

× 256) = 2 : (pL = 2, pH = 0)

fn = 3, 51

m = 0, 1, 48, 49

[Outline]

Determines the setting of storage area at initialization to the work area by the value
of “m”.

m

Function

0, 48

Does not copy data from storage area to work area at initialization.

1, 49

Copies data from storage area to work area at initialization.