beautypg.com

Gs (m pl ph fn m fn = 1, 49, Gs (m pl ph fn m fn = 2, 50 – CITIZEN CT-S300 User Manual

Page 119

background image

— 114 —

fn = 1, 49: Function 1

GS (M pL pH fn m fn = 1, 49

[Code]

<1d>H<28>H<4D>pL pH fn m

[Range]

(pL + pH

× 256) = 2 : (pL = 2, pH = 0)

fn = 1, 49

m = 1, 49

[Outline]

Copies the set value stored in work area to the storage area.

[Caution]

• This command allows writing to non-volatile memory. Therefore, using this

command frequently may result in breakage of non-volatile memory. Use this
command appropriately [10 times max./day].

• During execution of this command, the printer is in Busy state and stops receiving

operation. Therefore, data transmission from the host is prohibited.

fn = 2, 50: Function 2

GS (M pL pH fn m fn = 2, 50

[Code]

<1d>H<28>H<4D>pL pH fn m

[Range]

(pL + pH

× 256) = 2 : (pL = 2, pH = 0)

fn = 2, 50

m = 0, 1, 48, 49

[Outline]

Changes the set value of work area by the value of “m”.

m

Function

0, 48

Sets all set values of work area to the initial value described in the
specification.

1, 49

Copies the set value stored in storage area to the work area.
When there is no set value in storage area, sets the value to the initial
value described in the specification.