Redvolt charger (quad), Redvolt charger (quad) led indicators, Recharge redvolt batteries – RED DSMC POWER User Manual
Page 43: Red dsmc power operation guide

RED DSMC POWER OPERATION GUIDE
COPYRIGHT © 2014 RED.COM, INC
955-0038, REV-F
|
43
REDVOLT CHARGER (QUAD)
The REDVOLT Charger (Quad) is the fastest way to charge up to four REDVOLT or two REDVOLT XL batteries.
All batteries charge simultaneously, with up to 1.75 A distributed evenly to each cell until fully charged. The
REDVOLT Charger (Quad) can charge multiple REDVOLT or REDVOLT XL batteries in two (2) hours or less.
NOTE: The REDVOLT Charger (Quad) stops charging automatically if battery temperature exceeds 40˚C (104˚F),
or drops below 0°C (32°F).
REDVOLT CHARGER (QUAD) LED INDICATORS
The light on the REDVOLT Travel Charger displays a specific color and pattern indicating the state of charge.
COLOR PATTERN
DESCRIPTION
Green
Charger on, battery fully charged
Red/Green flashing (alternating)
Charger on, fail condition
Amber flashing
Charger on, battery connected and charging
RECHARGE REDVOLT BATTERIES
1. Connect the REDVOLT Charger (Quad) to a 100–240 VAC, 50/60 Hz power outlet.
2. Insert REDVOLT or REDVOLT XL battery into the charging bay.
3. Apply pressure until you hear a click to ensure the battery is fully seated.
4. Charge the battery until the LED indicator turns green, signalling a fully charged battery.
5. Press the Eject button on the desired battery charging bay(s) and remove the battery.
‒ REDVOLT: Press the Eject button to eject the battery.
‒ REDVOLT XL: Press both Eject buttons to eject the battery.
REDVOLT Charger (Quad)