Source-Assignable Art-Net Input
An Ethernet input on a Front of House (FOH) module can be mapped to a particular system source. Standard Art-Net
corresponds to System A, so it doesn't need to be re-mapped. A standard Art-Net output can be mapped to a
different system (B, C, or *) by enabling that option on the FOH module. When Ethernet remapping is enabled on a
module, the corresponding DMX inputs are disabled due to the increased processing requirements for handling the
network packets.
For example, access the I/O SUMMARY menu. Select "
in
" to open CONFIGURE INPUTS menu. At the first DMX
input, change
Ja
to
ETHa
by scrolling with arrows and then pressing "
done
." Once the input is set to ETHa
(Ethernet), the second DMX input becomes disabled (noted by
-x-
)
.
10
11
RESET
PORT 1
PORT 2
ETHERNET
Z-N
X-N
Y-N
DMX
TRUNK
DATA
LINK
Rx
Tx
Z-X
Y-Z
X-Y
FRONT of HOUSE MODULE
MODEL 20-9680-8615
6
AC LINE VOLTS
208V/15A
ZØ-N
XØ-YØ
YØ-ZØ
OR BRANCH CIRCUIT USE ONLY
3
4
5
DMX INPUTS
ZØ-XØ
3
7
DMX Rx
RDM Rx
RDM Tx
RDM Tx
8
4
RESET
1
RDM Rx
DMX Rx
DMX Rx
RDM Tx
RDM Rx
2
DMX
9
5
Front of House Breakout Module
Ethernet Ports (1 & 2) -
Source-assignable Art-Net
input ports.
DMX Input Port (2) - DMX512 input ports. Mutually exclusive
with the Ethernet ports. If an Ethernet port is assigned to a
source, this pair of DMX connectors are disabled.
DMX inputs
(E will be highlighted)
New Ethernet
The second DMX
input configuration
input becomes disabled.