PRG SERIES 400
®
POWER AND DATA DISTRIBUTION SYSTEM USER MANUAL
13
CONTROLS AND INDICATORS
Series 400 Rack
The PRG Series 400 Rack unit is the main power and data distribution hub for the system. The Rack houses up to six
Breaker Modules of any type, which can include a Front of House Breaker Module. The Rack provides a built-in LED
Meter Module that monitors system current and voltage, and additional space for installing optional expansion
components such as Series 400 Ethernet Switches and/or Virtuoso® Nodes. System-wide functions can be
controlled at the Rack, including power up, power down and testing.
The following illustrations provide a detailed description of standard rack connections, controls and indicators in an
example configuration.
Figure 1-8: Rack Components / Front View
YØ-ZØ
5
CIRCUIT
15A x 6
120V
TRUNK
CIRCUIT
15A x 6
120V
B
A
TRUNK
CIRCUIT
15A x 6
120V
TRUNK
B
XØ-YØ
1
YØ-ZØ
2
XØ-YØ
4
ZØ-XØ
3
YØ-ZØ
5
6
RDM Rx
DMX Rx
RDM Tx
RESET
DMX
A B
PORT 2
POWER / DATA
DISTRIBUTION
S-400
TRUNK
POWER / DATA
Tx
LINK
Rx
ETHERNET
DATA
SYSTEM
DISTRIBUTION
S-400
15A x 12 CIRCUITS
MODEL 20-9680-1915
YØ AMPS
120V
6
NEUT AMPS
X Ø AMPS
ZØ AMPS
ZØ-XØ
3
YØ-ZØ
5
YØ VOLTS
TRUNK
1
2
4
3
Z Ø VOLTS
Ø -N
5
Ш -Ш
MAX
PER Ø
400A
PORT 1
15A x 12 CIRCUITS
MODEL 20-9680-1915
INPUT 2
INPUT 1
120V
RESET
S-400
PORT 2
A B
TRUNK
POWER / DATA
LINK
DISTRIBUTION
SYSTEM
ETHERNET
DATA
S-400
ZØ-XØ
ZØ-XØ
ZØ-XØ
TRUNK
CIRCUIT
15A x 6
120V
B
XØ-YØ
1
YØ-ZØ
2
15A x 6
120V
TRUNK
CIRCUIT
A
XØ-YØ
1
YØ-ZØ
2
XØ-YØ
4
ZØ-XØ
3
YØ-ZØ
5
XØ-YØ
4
ZØ-XØ
3
RDM Tx
Rx
PORT 1
15A x 12 CIRCUITS
MODEL 20-9680-1915
PORT 1
15A x 12 CIRCUITS
MODEL 20-9680-1915
120V
RDM Rx
6
RDM Tx
DMX Rx
INPUT 1
INPUT 2
DMX
120V
RESET
6
INPUT 1
INPUT 2
SYSTEM
TRUNK
Tx
LINK
Rx
PORT 2
A B
ETHERNET
DATA
POWER / DATA
DISTRIBUTION
S-400
PORT 2
A B
PORT 1
15A x 12 CIRCUITS
MODEL 20-9680-1915
RDM Rx
DMX Rx
RESET
DMX
120V
RDM Tx
6
SYSTEM
TRUNK
ZØ-XØ
ZØ-XØ
TRUNK
CIRCUIT
15A x 6
120V
B
XØ-YØ
YØ-ZØ
XØ-YØ
ZØ-XØ
YØ-ZØ
15A x 6
15A x 6
120V
TRUNK
CIRCUIT
A
XØ-YØ
1
YØ-ZØ
2
15A x 6
120V
CIRCUIT
TRUNK
CIRCUIT
120V
B
A
XØ-YØ
4
ZØ-XØ
3
YØ-ZØ
5
DISTRIBUTION
PORT 1
DMX Rx
RDM Rx
RDM Tx
INPUT 1
INPUT 2
DMX
TRUNK
Tx
LINK
Rx
PORT 2
A B
SYSTEM
ETHERNET
DATA
PORT 1
15A x 12 CIRCUITS
MODEL 20-9680-1915
RDM Rx
120V
RESET
6
RDM Tx
INPUT 1
INPUT 2
DMX Rx
RESET
DMX
Tx
Rx
POWER / DATA
RDM Rx
DMX Rx
INPUT 1
INPUT 2
DMX
TRUNK
POWER / DATA
Tx
LINK
SYSTEM
ETHERNET
DATA
DISTRIBUTION
S-400
TRUNK
Tx
LINK
Rx
PORT 2
A B
ETHERNET
DATA
ZØ-XØ
CIRCUIT
15A x 6
120V
TRUNK
CIRCUIT
A
XØ-YØ
1
YØ-ZØ
2
15A x 6
120V
TRUNK
CIRCUIT
15A x 6
120V
B
A
XØ-YØ
4
3U Breaker Module (up to 6) - hot-swappable
chassis module which supplies AC power to
individually protected branch circuits via Trunk
connectors (mounted on rear panel).
Additional Space - 3U of rack space for adding
third-party signal processing devices.
LED Meter Module - provides both current and
voltage metering utilizing seven digital LED displays.
Rolling Rack - rugged rack enclosure unit, which
provides 18U for installation of modular components.
Front Rack Light - provides illumination for
front side of rolling rack.
EXAMPLE CONFIGURATION
S400 Rack Components May Vary