Breakout box mounting options – PRG S400 User Manual 3.1 User Manual

Page 39

background image

PRG SERIES 400

®

POWER AND DATA DISTRIBUTION SYSTEM USER MANUAL

33

Breakout Box Mounting Options

Breakout Boxes can be hung horizontally or vertically from any appropriate truss or structure. The Breakout Box
provides threaded holes for mounting by wingbolts, along with two additional holes for attaching a clamp bracket or a
variety of other hooks. The Mega-Claw truss hook is shown in these examples, however, other compatible truss
hooks are available from different manufacturers.

CAUTION:

A safety cable should be used in all mounting configurations. Attach as shown.

Wingbolt

Wingbolts are provided for mounting on standard 2-inch round truss pipe.

Figure 2-13: Wingbolt Mounting Method

Clamp Bracket Rail

In order to accommodate other mounting hooks, a clamp bracket rail (also used with VARI

❋LITE® Series 1000™,

2000™ and 3000™ luminaires) can be attached. The bracket requires two bushings, screws, nuts and the bracket
itself (refer to

"Accessories"

on page 12 for part numbers).

Figure 2-14: Installing Clamp Bracket

Wingbolts

Truss Pipe

Breakout Box

15A 208V MODEL SHOWN

Rack Components May Vary

Attach safety cable
at two hole locations

Safety Cable

SIDE VIEW

Bracket

Truss Hook Hardware
(not provided)

Bracket

Bushing

Locking Mechanism

Press up when
installing or releasing

Truss Hook
(not included)

Screw

Nut

1. Install bushings.
2. Install bracket, locking into place.
3. Install truss hook.

Procedure: