Appendix B: Reporting codes

82

NX-8E Control Panel Installation Manual

Loc. Description

Default

Setting

Segment 1 = Event number for output 3

2 (24-hour alarm)

Segment 2 = Timing for output 3

10 (seconds)

50

Auxiliary output 4 event/times

Segment 1 = Event number for output 4

21 (armed state)

Segment 2 = Timing for output 4

0 (follow condition)

51

Autotest control

Segment 1 = Autotest interval

0 = Days

1 = Hours

2 = Days and suppresses the test if any report has

been sent w ithin the last interval

3 = Hours and suppresses the test if any report has

been sent w ithin the last interval

1

Segment 2 = Autotest interval from 1 to 255 days or

hours based on Segment 1

24 (hours)

Segment 3 = Hour of the autotest in 24-hour time

format

2 (0200)

Segment 4 = Autotest report time, min. after the hour.

0

52

Opening/automatic disarm times

Segment 1 = Hour of the opening time

8

Segment 2 = Minutes after the opening time

0

53

Closing/automatic arming times

Segment 1 = Hour of the closing/auto arming time

20

Segment 2 = Minutes. after hour of closing/auto

arming time

0

54

Days of week each partition (1 to 8) is open

Segments 1 to 8 options

1

2

3

4

5

6

7

8

1 = Sunday

1

1

1

1

1

1

1

1

2 = Monday

2

2

2

2

2

2

2

2

3 = Tuesday

3

3

3

3

3

3

3

3

4 = Wednesday

4

4

4

4

4

4

4

4

5 = Thursday

5

5

5

5

5

5

5

5

6 = Friday

6

6

6

6

6

6

6

6

7 = Saturday

7

7

7

7

7

7

7

7

8 = Reserved

8

8

8

8

8

8

8

8

55

Days of week auto arming will occur in partitions 1 to 8

Segments 1 to 8 options

1

2

3

4

5

6

7

8