Appendix B: Reporting codes
80
NX-8E Control Panel Installation Manual
Loc. Description
Default
Setting
39
Keypad sounder control
Segment 1
1 = Keypad sounds for telephone line cut w hen in the armed state
2 = Keypad sounds for telephone line cut w hen in the disarmed state
3 = Keypad sounds upon AC pow er failure
4 = Keypad sounds upon low battery detection
5 = Keypad sounds during cross zone trip time
6 = Keypad sounds for tamper alarm
7 = Reserved
8 = Keypad sounds for expander trouble
40
System timers
Segment 1 = Dynamic battery test duration (0 to 255)
0 (minutes)
Segment 2 = AC failure report delay (0 to 255
minutes)
5 (minutes)
Segment 3 = Pow er up delay (0 to 60)
60 (seconds)
Segment 4 = Siren time (1 to 254).
8 (minutes)
Segment 5 = Telephone line cut delay (0 to 255)
0 (seconds)
Segment 6 = Cross zone time (0 to 255)
5 (minutes)
Segment 7 = Chime time in 50 mS increments (0 to
255)
3
Segment 8 = Dialer delay (15 to 255)
30 (seconds)
Segment 9 = Fire alarm verification time (120 to 255)
0 (seconds)
Segment 10 = Listen-in time (0 to 255)
0 (seconds)
Segment 11 = Zone monitor timer (0 to 255)
0 (days)
Segments 12 to 14 = Reserved
41
Special features
Segment 1
1 = Enable six-digit code option
2 = Require valid user code entry for *, 9, 8 and * 9, 9
functions to w ork
3 = Enable auto cancel/abort
4 = Enable w alk test mode
5 = Enable auto force-arming w ith keyfob or keysw itch
6 to 8 = Reserved
42
Go to program code
9, 7, 1, 3, 0, 0