Chapter 2: Reporting codes
56
NX-8E Control Panel Installation Manual
Location 209 - Home automation protocol
Location 209 has one segment of numerical data.
The NX-8E home automation protocol can operate in one of two possible modes,
binary or ASCII. Consult the home automation application information to
determine the proper mode for your application and program it in Location 209.
The default is Off (binary).
Option 1.
LED Off = Binary (default)
LED On = ASCII
Option 2
On if serial port supervised. When enabled, the serial port expects to be polled at least once
every 4 minutes. If it doesn’t get polled within 4 minutes, then an expander trouble module 177
will be logged.
Default is off.
Options 3 to 8 = Reserved
Location 210 - Transition-based broadcasts
Location 210 has two segments of feature selection data.
The NX-8E can be programmed to automatically send information to the home
automation system whenever there has been a change in this informaiton. This is
referred to as “transition-based broadcasting”. Which information packets use
transition-based broadcasting is dependent upon the application and the
capabilities of the home automation system. Use Location 210 to enable and
disable the appropriate transition-based broadcasts (consult the home
automation application information).
Segment 1
1. Reserved.
2. Interface configuration at power-up/end of download/program mode.
3. and 4. Reserved.
5. Zone status message.
6. Zones snapshot message.
7. Partition status message.
8. Partitions snapshot message.
Segment 2
1. System status message.
2. X-10 message received.
3. Log event message.
4. Keypad message received.
5 to 8. Reserved.