Interlogix NX-8E Installation Manual User Manual
Page 33
Chapter 2: Reporting codes
NX-8E Control Panel Installation Manual
29
Location 24 - Entry/exit times
Location 24 has six segments of numerical data. Use this location to program the
entry/exit times (there are two separate entry/exit times).
Segment 1 - Entry time 1. Entry time used when a delay 1 zone type initiates an entry delay.
Default is 30, valid entries 30 to 255 seconds.
Segment 2 - Exit time 1. Exit time used for all zones designated as delay 1. Default is 60, valid
entries 45 to 255 seconds.
Segment 3 - Entry time 2. Entry time used when a delay 2 zone type initiates an entry delay.
Default is 30, valid entries 30 to 255 seconds.
Segment 4 - Exit time 2. Exit time used for all zones designated as delay 2. Default is 60, valid
entries 45 to 255 seconds.
Segment 5 and 6 - Reserved
Locations 25 to 36 - Zone type and partition selection
Zones are programmed to be one of thirty different types. To customize a zone
type, see Locations 110 to 169 (these are considered advanced programming
and are only to be changed with a thorough understanding of the operation of
each bit.
Caution:
We recommend the installer bench test any custom zone types to
ensure proper operation prior to making changes to a live system.
Use zone types 17 through 20 for wireless, or for hardwired zones using
European double EOL configurations.
Table 7: Zone types
Zone type
Description
1. Day zone
Instant when the system is armed; trouble zone when the system is
disarmed.
2. 24-hour audible
Creates an instant yelping siren alarm regardless of the armed state
of the control panel.
3. Entry/exit delay 1
A trip starts entry delay 1. The lack of a trip during exit delay enables
the automatic bypass or instant mode if programmed.
4. Follower with auto
bypass disabled
Instant when the system is armed and no entry or exit delays are
being timed. It is delayed 1 time during entry and exit. It does not
automatically bypass even if enabled in segment 1 of Location 23.
5. Interior follower with
auto bypass
Instant when the system is armed and no entry or exit delay is being
timed. It is delayed 1 time during entry and exit. It automatically
bypasses if enabled in segment 1 of Location 23.