Chapter 2: Reporting codes
NX-8E Control Panel Installation Manual
39
Location 50 - Auxiliary output 4 event and times
Location 50 has two segments of numerical data.
Segment 1 - Use Table 8 below to select the event that activates auxiliary output 4.
Segment 2 - Program the timing from 0 to 255 (minutes or seconds, depending on data
programmed in Location 46, segment 1). Programming a 0 makes the output follow the event.
Default is 10 (seconds).
Table 8 below describes the auxiliary output event selections.
Table 8: Auxiliary output events selection
0 = Burglary alarm
a
1 = Fire alarm (includes keypad panic)
a
2 = 24-hour alarm (includes keypad panics and
zone types 2 and 7)
a
3 = Trouble alarm (does not include phone
trouble)
a
4 = Tamper alarm
a
5 = Yelping siren (burglary)
6 = Temporal siren (fire)
7 = Any siren
8 = Any bypass
9 = AC fail
10 = Low battery (does not include expansion
battery)
11 = Duress
a
12 = Aux 1 keypad zone (keypad fire panic)
a
13 = Aux 2 keypad zone (keypad emergency
panic)
a
14 = Panic keypad zone (keypad police panic)
a
15 = Keypad tamper
16 = Autotest
a
17 = Alarm memory
18 = Entry
19 = Exit
20 = Entry or exit
21 = Armed state (follows Armed LED)
22 = Disarmed state
23 = Ready
24 = Not ready
25 = Fire (follows Fire LED)
26 = Fire trouble
27 = Chime (chime must be on at keypad)
28 = Expander trouble
a
29 = Dynamic battery test time
30 = Open period
31 = Closed period
32 = Listen in
33 = Line seizure
34 = Ground start (momentary at start of phone
dial)
35 = Fail to communicate
36 = Telephone line fault
37 = Program mode
38 = Download in process (for modem
connection only)
39 = Smoke power
40 = Short circuit (overcurrent panel only)
41 = Box tamper
42 = Siren tamper
43 = Any open