Chapter 2: Reporting codes

32

NX-8E Control Panel Installation Manual

Location 25
Zones 1 to 8 zone type

Location 25 has eight segments of numerical data. Use this location to
program the zone type for zones 1 to 8. Use segment 1 for zone 1,
segment 2 for zone 2, etc. The segment defaults are 3, 5, 6, 6, 6, 6, 6,
6.

Location 26
Zones 1 to 8 partition

Location 26 has eight segments of feature selection data. Use this
location to select the partitions (1 to 8) that zones 1 to 8 reside in.
Each segment corresponds to a zone (segment 1 to zone 1, segment
2 to zone 2, etc.). In each segment, enter 1 for partition 1 through 8 for
partition 8.

Location 27
Zones 9 to 16 zone types

Location 27 has eight segments of numerical data. Use this location to
program the zone type for zones 9 to 16. Use segment 1 for zone 9,
segment 2 for zone 10, etc. The segment defaults are 6, 6, 6, 6, 6, 6,
6, 6.

Location 28
Zones 9 to 16 partition

Location 28 has eight segments of feature selection data. Use this
location to select the partitions (1 to 8) that zones 9 to 16 reside in.
Each segment corresponds to a zone (segment 1 to zone 9, segment
2 to zone 10, etc.). In each segment, enter 1 for partition 1 through 8
for partition 8.

Location 29
Zones 17 to 24 zone
types

Location 29 has eight segments of numerical data. Use this location to
program the zone type for zones 17 to 24. Use segment 1 for zone 17,
segment 2 for zone 18, etc. The segment defaults are 6, 6, 6, 6, 6, 6,
6, 6.

Location 30
Zones 17 to 24 partition

Location 30 has eight segments of feature selection data. Use this
location to select the partitions (1 to 8) that zones 17 to 24 reside in.
Each segment corresponds to a zone (segment 1 to zone 17,
segment 2 to zone 24, etc.). In each segment, enter 1 for partition 1
through 8 for partition 8.

Location 31
Zones 25 to 32 zone
types

Location 31 has eight segments of numerical data. Use this location to
program the zone type for zones 25 to 32. Use segment 1 for zone 25,
segment 2 for zone 26, etc. The segment defaults are 6, 6, 6, 6, 6, 6,
6, 6.

Location 32
Zones 25 to 32 partition

Location 32 has eight segments of feature selection data. Use this
location to select the partitions (1 to 8) that zones 25 to 32 reside in.
Each segment corresponds to a zone (segment 1 to zone 25,
segment 2 to zone 26, etc.). In each segment, enter 1 for partition 1
through 8 for partition 8.

Location 33
Zones 33 to 40 zone
types

Location 33 has eight segments of numerical data. Use this location to
program the zone type for zones 33 to 40. Use segment 1 for zone 33,
segment 2 for zone 34, etc. The segment defaults are 6, 6, 6, 6, 6, 6,
6, 6.

Location 34
Zones 33 to 40 partition

Location 34 has eight segments of feature selection data. Use this
location to select the partitions (1 to 8) that zones 33 to 40 reside in.
Each segment corresponds to a zone (segment 1 to zone 33 segment
2 to zone 34, etc.). In each segment, enter 1 for partition 1 through 8
for partition 8.