Location 51 - autotest control – Interlogix NX-8E Installation Manual User Manual
Page 44
Chapter 2: Reporting codes
40
NX-8E Control Panel Installation Manual
44 = Any short
45 = Any fault (short on nonfire zone)
46 = Any alarm (includes 24-hour zones but not
keypad panics)
a
47 = Beeping keypad
48 = Code entry
a b
49 = Key fob function 1
a c
50 = Key fob function 2
a c
51 = Always on
52 = Alarm flash
53 = Armed away
54 = Armed stay
55 = Aux comm fail
56 = CP-01 . Progress annunciation (output
toggles slowly during exit delay, then fast during
the last 10 seconds; on steady during entry
delay)
a. These events are 1 second if set to follow condition.
b. When event 48 is programmed, it is possible to program a user code’s authorization to select
which outputs a particular code activates. In *6, user code authority assignment mode, when LED
8 is on for authorization, then LEDs 1 to 2 correspond to that code activating outputs 1 to 2
respectively.
c. Events 49 and 50 require one or more of the following to operate: NX-148E-RF, NX-408E, NX-
448E wireless receivers, NX-548E or NX-1700E/NX-1710E card readers.
Location 51 - Autotest control
Location 51 has four segments of numerical data.
Segment 1 - Program the autotest interval.
Enter 0 if the interval is in days (if the panel tests once daily, program one day rather than once
every 24 hours)
Enter 1 if the interval is in hours (default)
Enter 2 if the interval is in days and suppresses the test if any report has been sent within the
last autotest interval.
Enter 3 if the interval is in hours and suppresses the test if any report has been s ent within the
last autotest interval.
Segment 2 - Program the autotest interval from 1 to 255 hours/days. Default is 24 (hours).
Segment 3 - Program the autotest report hour in 24-hour (military time) format (if the interval is
in hours, this segment is ignored). Default is 2 (0200).
Segment 4 - Program the autotest report time, as the number of minutes after the hour. Default
is 0.