Interlogix NX-8E Installation Manual User Manual
Page 107
Glossary
NX-8E Control Panel Installation Manual
103
Dual/split/multiple reports
The NX-8E sends communication reports to three different
phone numbers for dual, split, or multiple reports selectable by
event or partition. (Locations 4, 10, 16, and 18)
Duress code
If programmed, the NX-8E sends a duress signal whenever the
panel is armed or disarmed with this code. The user code is 254
if open/close reports are sent. (Location 44)
Dynamic battery test
If programmed, the NX-8E performs a dynamic battery test for a
selected duration the first time the panel is armed or disarmed
every day, as well as being by using *, 4 (test function). if the
panel is not armed or disarmed during the day, it performs the
test at midnight. The NX-8E can also be programmed to report
a missing battery test every 12 seconds. (Locations 37 and 40)
Early to open/late to close
If an opening occurs before the opening times the NX-8E sends
an early open report. If a closing does not occur on or before
the designated closing time, the NX-8E sends a late to close
report.
End-of-line resistor defeat
If programmed, the NX-8E makes zones 1 to 8 for normally
closed operation only, eliminating the need for the end-of-line
resistors on these zones. When a zone is programmed for
normally closed operation, a short on that zone does not
change the loop condition, and an open on that zone produces
a faulted condition. Any priority zone ignores this feature.
(Locations 110 to 169)
Entry guard
This unique low level arming mode reduces the most common
source of false alarms. When armed with the Instant LED on,
the opening of any zones designated as an entry guard zone
initiates the keypad sounder and starts the entry delay before
creating an alarm. All other zones function as normal. This
arming mode encourages system owners to use their system
more frequently when the premises are occupied. (Locations
110 to 169)
Event log
Up to 512 events are stored in memory along with the date and
time of the event. These events are viewed later through
downloading or from a display keypad. All reportable events
report to the log.
Exit error
If enabled, the NX-8E sends an exit error report if an entry/exit
zone is faulted at the instant the exit delay expires. This report
is sent along with the user number that armed the system, if the
panel is not disarmed before the entry delay expires. The alarm
report is also sent. Even if this feature is not enabled, the siren
sounds if any entry/exit zone is faulted at the instant the exit
delay expires. (Location 23)
Expander trouble
If enabled, the NX-8E reports expander trouble to the central
station. This condition illuminates the Service LED on the
keypad even if not reported. (Location 37)
Note: The keypads are considered expanders. The expansion
device number that reports can be found in Table 16 on page
70.