Control panel programming – Interlogix NX-8E Installation Manual User Manual
Page 18
Chapter 2: Reporting codes
14
NX-8E Control Panel Installation Manual
assigned authority levels to all user numbers, or you can press # to exit
assigning authority level programming.
Table 5: LED features
LED
Attributes if LED 8 is off
Attributes if LED 8 is on
1
Reserved
Activate output 1
2
Armed only
Activate output 2
3
Arm only after close window
Activate output 3
4
Master arm/disarm (can program other
codes)
Activate output 4
5
Arm/disarm code
Arm/disarm
6
Allowed to bypass zones
Bypass zones
7
Code sends open/close reports
Open/close reporting
8
If this LED is on, LEDs 1 to 7 use the
column to the right.
If this LED is off, LEDs 1 to 7 use the
column to the left.
Note:
Any master arm/disarm code can add or change a user code if the master
code has access to the same partitions as the code being added/changed.
Consequently, when programming the user codes for a partitioned system, leave
at least one code (can be go to program code if enabled in Location 43) access
to all partitions or you will not be able to add new users. If you want the end user
to be able to add new codes, you must remove the partition authority from all
blank codes.
Entering *, 9, 8 while the system is disarmed, causes the control panel to do a
callback for a download. A valid user code is required after pressing *, 9, 8 if it is
enabled in Location 41.
Entering *, 9, 9 while the system is disarmed causes the control panel to seize
the phone line for a download. A valid user code is required after pressing *, 9, 9
if it is enabled in Location 41.
Control panel programming
Programming the control panel requires you to enter program mode, select the
module to program, program a location, and then exit the location and program
mode.