Interlogix NX-8E Installation Manual User Manual
Page 57
Chapter 2: Reporting codes
NX-8E Control Panel Installation Manual
53
Location 184
Zones 105 to 112 zone
types
Location 184 has eight segments of numerical data. Use this location
to program the zone type for zones 105 to 112. Use segment 1 for
zone 105, segment 2 for zone 106, etc. The segment defaults are 6,
6, 6, 6, 6, 6, 6, 6.
Location 185
Zones 105 to 112
partition
Location 185 has eight segments of feature selection data. Use this
location to select the partitions (1 to 8) that zones 105 to 112 reside in.
Each segment corresponds to a zone (segment 1 to zone 105,
segment 2 to zone 106, etc.). In each segment, enter 1 for partition 1
through 8 for partition 8.
Location 186
Zones 113 to 120 zone
types
Location 186 has eight segments of numerical data. Use this location
to program the zone type for zones 113 to 120. Use segment 1 for
zone 113, segment 2 for zone 114, etc. The segment defaults are 6,
6, 6, 6, 6, 6, 6, 6.
Location 187
Zones 113 to 120
partition
Location 187 has eight segments of feature selection data. Use this
location to select the partitions (1 to 8) that zones 113 to 120 reside in.
Each segment corresponds to a zone (segment 1 to zone 113,
segment 2 to zone 114, etc.). In each segment, enter 1 for partition 1
through 8 for partition 8.
Location 188
Zones 121 to 128 zone
types
Location 188 has eight segments of numerical data. Use this location
to program the zone type for zones 121 to 128. Use segment 1 for
zone 121, segment 2 for zone 122, etc. The segment defaults are 6,
6, 6, 6, 6, 6, 6, 6.
Location 189
Zones 121 to 128
partition
Location 189 has eight segments of feature selection data. Use this
location to select the partitions (1 to 8) that zones 121 to 128 reside in.
Each segment corresponds to a zone (segment 1 to zone 121,
segment 2 to zone 122, etc.). In each segment, enter 1 for partition 1
through 8 for partition 8.
Location 190
Zones 129 to 136 zone
types
Location 190 has eight segments of numerical data. Use this location
to program the zone type for zones 129 to 136. Use segment 1 for
zone 129, segment 2 for zone 136, etc. The segment defaults are 6,
6, 6, 6, 6, 6, 6, 6.
Location 191
Zones 129 to 136
partition
Location 191 has eight segments of feature selection data. Use this
location to select the partitions (1 to 8) that zones 129 to 136 reside in.
Each segment corresponds to a zone (segment 1 to zone 129,
segment 2 to zone 130, etc.). In each segment, enter 1 for partition 1
through 8 for partition 8.
Location 192
Zones 137 to 144 zone
types
Location 192 has eight segments of numerical data. Use this location
to program the zone type for zones 137 to 144. Use segment 1 for
zone 137, segment 2 for zone 138, etc. The segment defaults are 6,
6, 6, 6, 6, 6, 6, 6.
Location 193
Zones 137 to 144
partition
Location 193 has eight segments of feature selection data. Use this
location to select the partitions (1 to 8) that zones 137 to 144 reside in.
Each segment corresponds to a zone (segment 1 to zone 137,
segment 2 to zone 138, etc.). In each segment, enter 1 for partition 1
through 8 for partition 8.