TL

Trigger

Level

[ 2500sub01 ]

Set the trigger level for rising edge start of measurement. Permitted values are in the

range 0…262143.

Master (PC / PLC) sends

Device responds

Result

TL T+99999

Request: TL=99999

TL_1000 OK

Setting: TL=1000

With regard to the trigger commands SD and MT, a check weighing will automatically start

when the weight overshoots by e.g. 1.000d (increments), e.g. 100,0 g.

Factory default: 199999


TE Trigger

Edge

[ 2500sub02 ]

Issuing the TE command selects rising or falling edge trigger. Parameter = 0 select falling

edge and parameter = 1 select rising edge.

Master (PC / PLC) sends

Device responds

Result

TE E:001

Request: TE=1

TE_0 OK

Setting: TE=0

Factory default: 0 [falling edge]

Note:

This command cannot be used together with the TL command.

TR

Trigger

RPDO2 [ 00 80 ]

[This command will start the measuring cycle in the same way as the hardware trigger

input. The result is sent as a TPDO2 with source=LDM#.]

Master (PC / PLC) sends

Device responds

Result

TR OK

Trigger started

Note:

This function can be used as a soft trigger in a check weigher application (firmware

88.183) or to start a filling process (firmware 88.184)

[ Special returned values are:

- 99999 = trigged measurement in progress

- 88888 = Re-Trigger in progress