beautypg.com

Flintec MCS-64 CANbus User Manual

Page 24

background image


Manual MCS-64 Page 24

Index

Sub-
index

Name

Type

Attri-
bute

Default-value

Meaning

2C00 -
2C3F

for
LDM
0..63

0
1
2
3
4
5

Number of entries.
Mass Flow Control.
Mass Flow Status.

UI8
UI8
UI8

ro
rw
ro

2

Number of entries in the mass flow control words.
Mass Flow control word.
Mass Flow status/info word

2CFF

Number of entries.
As for 2C00-2C3F

UI8
I32

ro
wo

2

Number of entries in the mass flow control words.
As for 2C00 – 2C3F, except this is WRITE ONLY and the settings are
broadcasted to all LDMs.

6401






0
1
2
3
4
5
6

Number of entries
Gross weight
Net Weight
Tare
Dosed weight
Dosed tare
Average weight

UI8
I16
I16
I16
I16
I16
I16

ro
ro
ro
ro
ro
ro
ro

6

Number of entries in the 16 bit analog input module (PC6D only)
These entries are mandatory according to DS401. They are the same as for
index 6402, but shifted 8 bits to the right (value/256).

6402







0
1
2
3
4
5
6
7

Number of entries
Gross weight
Net Weight
Tare
Dosed weight
Dosed tare
Average weight
A/D sample

UI8
I32
I32
I32
I32
I32
I32
I32

ro
ro
ro
ro
ro
ro
ro
ro

7

Number of entries in the 32 bit analog input module (PC6D only)
These values are the internal long integer representation of the weight (the
integer values are multiplied by 10^dp [2300sub0B]).
Index 6402 is a sub-set of index 2001.

6403






0
1
2
3
4
5
6

Number of entries
Gross weight
Net Weight
Tare
Dosed weight
Dosed tare
Average weight

UI8
REAL32
REAL32
REAL32
REAL32
REAL32
REAL32

ro
ro
ro
ro
ro
ro
ro

6

Number of entries in the float analog input module (PC6D only)
These values are the floating-point representation of the weight as they are
transmitted in the PDO1(tx).
Index 6403 is a replica of index 2000.