The CANopen SDOs is a confirmed service, and overrun does not occur if the CAN controller

only communicates with the Gateway in the PRE-OPERATIONAL state. When a SDO has

been received by the controller no further communication takes place until the service has

been acknowledged (or a timeout occurs). However, other types of communication may fill

the Gateways internal buffer storage. In this event, the Gateway will issue an Overrun

Emergency message.

3.2 Communication

Profile

The parameters which are critical for communication are determined in the communication

profile.

This includes the data for manufacturer's product nomenclature, for identification, or the

parameters for object mapping.

Abbreviations used in Tables:

ro

read only

rw

read / write

wo

write only

(read will not be regarded as an error, but returns undefined results)

UI8

Unsigned8

UI16

Unsigned16

UI32

Unsigned32

I32

Signed32

REAL32

32 bit IEEE754 floating point

VS

Visible String

3.3 Object

Directory

The object directory of the CAN communication module is described below:

Please look the following pages.