Flintec MCS-08 User Manual
Page 8
MCS-08 Technical Manual, Rev. 1.04 December 2012
Page 8 of 52
Gateway Modules
General
Internal bus system
Communication with up to
8x type MCS-08AD and up to 8x type MCS-08IO and 1x type MCS-08DP
Serial interface RS232C
9600 baud (8, N, 1), used as service interface, communication to each
connected type MCS-08AD respective
type MCS-08IO respective type MCS-08DP
Response time
< 4 ms (delay after each read or write command)
Power supply:
DC power supply
10 to 28 VDC, < 100 mA, not galvanically isolated
Environment and Enclosure:
Operating temperature
Between -10 °C and +40 °C at maximum 85% RH, non-condensing
Enclosure & protection class Polyamide, for DIN-rail mounting, protection class IP20
Dimensions & weight
99 x 45 x 114.5 mm (L x W x H), weighs appr. 150 g
Profibus DP Gateway Module: Type MCS-08PB
Communication:
Profibus DP-V0 + DP-V1
9.6 kbit/s to 12 Mbit/s (automatic), galvanically isolated interface
Address range
1...126
ProfiNet Gateway Module: Type MCS-08PN
Communication:
ProfiNet
100 Mbit/s (full duplex), galvanically isolated interface
IP settings
DHCP or manual setup by PC software
Modbus RTU Gateway Module: Type MCS-08MB
Communication:
Serial interface RS485A
Serial interfac RS485, 1200 to 57600 baud (8N1, 7E1, 7O1),
bus capability up to 31 units
Address range
1...31
Ethernet TCP/IP Gateway Module: Type MCS-08EN
Communication:
Ethernet TCP/IP
10 Mbit/s (full duplex), galvanically isolated interface
IP settings
Manual setup by PC software
Other
Web client interface
Digital I/O Module: Type MCS-08IO
Digital I/O:
Inputs
4 opto-isolated inputs (12...30 V DC)
Outputs
4 potential-free NO relays, 1A @ 250 V AC, 30 V DC
Input function
Control input to communication interface
Output function
Control output from communication interface
Communication and Setup:
Setup & calibration
By PC software via gateway module, backup data stored on PC
Response time
< 4 ms (delay after each read or write command)
Power supply:
DC power supply
10 to 28 VDC, < 100 mA, not galvanically isolated
Environment and Enclosure:
Operating temperature
Between -10 °C and +40 °C at maximum 85% RH, non-condensing
Enclosure & protection class Polyamide, for DIN-rail mounting, protection class IP20
Dimensions & weight
99 x 22.5 x 114.5 mm (L x W x H), weighs appr. 100 g