Plc output to mcs-08px input – Flintec MCS-08 User Manual
Page 31
MCS-08 Technical Manual, Rev. 1.04 December 2012
Page 31 of 52
D7
D6
D5
D4
D3
D2
D1
D0
Error Codes
0000 1001
Calibration Errors
0000 0010
Span calibration in progress
0000 0011
Zero calibration in progress
0010 0010
System ready for calibration
MCS-08IO [x]
Byte
D7
D6
D5
D4
D3
D2
D1
D0
MCS-08IO [0]
+1
st
Byte
Input 4
Input 3
Input 2
Input 1
MCS-08IO [1]
+2
nd
Byte
Input 4
Input 3
Input 2
Input 1
MCS-08IO [2]
+3
rd
Byte
Input 4
Input 3
Input 2
Input 1
MCS-08IO [3]
+4
th
Byte
Input 4
Input 3
Input 2
Input 1
MCS-08IO [4]
+5
th
Byte
Input 4
Input 3
Input 2
Input 1
MCS-08IO [5]
+6
th
Byte
Input 4
Input 3
Input 2
Input 1
MCS-08IO [6]
+7
th
Byte
Input 4
Input 3
Input 2
Input 1
MCS-08IO [7]
+8
th
Byte
Input 4
Input 3
Input 2
Input 1
PLC Output to MCS-08Px Input
MCS-
08Px
1
st
Dword
(W)
D31 D30 D29 D28 D27 D27 D25 D24 D23 D22 D21 D20 D19 D18 D17 D16
Not in use
D15 D14 D13 D12 D11 D10 D9
D8
D7
D6
D5
D4
D3
D2
D1
D0
Not in use
I/O
Write
Common Command
List
Data Selection
CMD
flag
Bit no.
1
st
Dword Description
D31…D9
Not in use
D8
0
I/Os are changed by PLC output to MCS-08Px input I/O
bytes. This flag does not need the New CMD command
I/O Write Control
1
I/Os are changed by Common Command List below:
1000- SET or 1001- RESET
D7
D6
D5
D4
0000
No error found
Common Command
List
0001
Zeroing command sent to all MCS-08AD modules
0010
Tare command sent to all MCS-08AD modules
0011
Clear command sent to all MCS-08AD modules
1000
SET all outputs of all MCS-08IO modules
(if I/O Write Control = 1)
1001
RESET all outputs of all MCS-08IO modules
(if I/O Write Control = 1)
D3
D2
D1
000
All active MCS-
08xx modules refer to D16…D31 of
MCS-08Px output to PLC input 1
st
Dword (default)
Data Selection
001
All active MCS-
08IO modules refer to D16…D31 of
MCS-08Px output to PLC input 1
st
Dword
010
All active MCS-
08AD modules refer to D16…D31 of
MCS-08Px output to PLC input 1
st
Dword
D0
Toggles
Apply commands which are listed in this table
New CMD