beautypg.com

Flintec MCS-08 User Manual

Page 26

background image

MCS-08 Technical Manual, Rev. 1.04 December 2012

Page 26 of 52

Address R/W

Word Command

Description

41001

R

1

System Status of
MCS-08AD and
MCS-08DP

D10

00: No module found at address [5]

D11

01: Module at address [5] is active

D12

00: No module found at address [6]

D13

01: Module at address [6] is active

D14

00: No module found at address [7]

D15

01: Module at address [7] is active

41002

R

1

System Status of
MCS-08IO

D0

IO [0]

00 = Module at address [0] not found
01 = Module at address [0] is active
10 = reserved
11 = reserved

D1

D2

IO [1]

00 = Module at address [0] not found
01 = Module at address [0] is active
10 = reserved
11 = reserved

D3

D4

IO [2]

00 = Module at address [0] not found
01 = Module at address [0] is active
10 = reserved
11 = reserved

D5

D6

IO [3]

00 = Module at address [0] not found
01 = Module at address [0] is active
10 = reserved
11 = reserved

D7

D8

IO [4]

00 = Module at address [0] not found
01 = Module at address [0] is active
10 = reserved
11 = reserved

D9

D10

IO [5]

00 = Module at address [0] not found
01 = Module at address [0] is active
10 = reserved
11 = reserved

D11

D12

IO [6]

00 = Module at address [0] not found
01 = Module at address [0] is active
10 = reserved
11 = reserved

D13

D14

IO [7]

00 = Module at address [0] not found
01 = Module at address [0] is active
10 = reserved
11 = reserved

D15

41003

R

1

Status of
MCS-08MB
Gateway

D0

System failure

D1

EEPROM failure

D2

External bus communication error

D3

A module was installed / removed

D4

No module found within the system

D5…D15 Not in use

41004

1

Not in use

41005

R

1

Status of
MCS-08AD [0]

D0

0

– System Ready

1

– System Busy

D1

0

– Error

1

– Data ok

D2

0

– Weight Stable

1

– Weight unstable

D3

0

– Gross Mode

1

– Net mode

D4

0

Not used

D5

0

– Weight / Force

1

– Count Mode

D6…D11 Not in use
D12

0

– Out of zero range 1 – Weight is in zero range

D13
D14
D15

Error Code

0

No Errors

1

ADC out of range

2

ADC over range

3

ADC under range

4

System error

5

In setup mode

6

Low/High voltage det.