Page 32 of 52

MCS-

08 AD

[0]*

2

nd

Dword

(W)

D31 D30 D29 D28 D27 D27 D25 D24 D23 D22 D21 D20 D19 D18 D17 D16
D15 D14 D13 D12 D11 D10 D9

D8

D7

D6

D5

D4

D3

D2

D1

D0

Next Dword defines the usage of this Dword

3

st

Dword

(W)

D31 D30 D29 D28 D27 D27 D25 D24 D23 D22 D21 D20 D19 D18 D17 D16

Not In Use

D15 D14 D13 D12 D11 D10 D9

D8

D7

D6

D5

D4

D3

D2

D1

D0

Not in use

Command List

Description of 2

nd

Dword (R)

CMD

flag


*Register address for MCS-08AD [1]: 4

th

…5

th

Dword,

MCS-08AD [2]: 6

th

…7

th

Dword,

MCS-08AD [3]: 8

th

…9

th

Dword,

MCS-08AD [4]: 10

th

…11

th

Dword,

MCS-08AD [5]: 12

th

…13

th

Dword,

MCS-08AD [6]: 14

th

…15

th

Dword,

MCS-08AD [7]: 16

th

…17

th

Dword definitions are same as 2

nd

– 3

rd

Dwords

Bit no.

3

rd

, 5

th

, 7

th

, 9

th

, 11

th

, 13

th

, 15

th

, 17

th

Dword Description

D31…D11

Not in use

D10
D9
D8
D7
D6

00000

No command selected

Command list

00001

Zero

00010

Tare

00011

Clear

00101

Start zero calibration

00110

Start span calibration. First load 2

nd

Dword with test weight,

then apply this command with New CMD.

01000

Operation mode selection. First load 2

nd

Dword with selected

value, then apply this command with New CMD.
0 = Count mode unipolar, 1 = Count mode bipolar, 2 Force
mode unipolar, 3 = Force mode bipolar, 4 = Weight mode
unipolar

01001

mV operation in Count Mode. First load 2

nd

Dword with

selected value, then apply this command with New CMD.
0 = 5mV, 1 = 10mV, 2 = 15 mV, 3 = 18mV

01010

Digital filter. First load 2

nd

Dword with selected value, then

apply this command with New CMD.
Filter values: 0 = Fast,….., 9 = Slow

D5
D4
D3
D2
D1

00000

Indicated weight

Description of 2

nd

Dword (R)

00001

Gross weight

00010

Tare weight

00011

Indicated weight (floating point type)

00100

Gross weight (floating point type)

00101

Tare weight (floating point type)

00110

Increased resolution for indicated weight

10000

Calibration status

D0

Toggle

Apply command (of the commands listed in this table)

New CMD



MCS-08IO [x]

Byte (W)

D7

D6

D5

D4

D3

D2

D1

D0

MCS-08IO [0]

+1

st

Byte (W)

Output 4 Output 3 Output 2 Output 1

MCS-08IO [1]

+2

nd

Byte (W)

Output 4 Output 3 Output 2 Output 1

MCS-08IO [2]

+3

rd

Byte (W)

Output 4 Output 3 Output 2 Output 1

MCS-08IO [3]

+4

th

Byte (W)

Output 4 Output 3 Output 2 Output 1

MCS-08IO [4]

+5

th

Byte (W)

Output 4 Output 3 Output 2 Output 1

MCS-08IO [5]

+6

th

Byte (W)

Output 4 Output 3 Output 2 Output 1

MCS-08IO [6]

+7

th

Byte (W)

Output 4 Output 3 Output 2 Output 1

MCS-08IO [7]

+8

th

Byte (W)

Output 4 Output 3 Output 2 Output 1