MCS-08 Technical Manual, Rev. 1.04 December 2012

Page 29 of 52

5.11. Profibus and ProfiNet Data Structure (for MCS-08Px only)

MCS-08Px Output to PLC Input

MCS-

08Px

1

st

Dword

(R)

D31 D30 D29 D28 D27 D27 D25 D24 D23 D22 D21 D20 D19 D18 D17 D16

Active MCS-08IO modules

Active MCS-08AD modules

D15 D14 D13 D12 D11 D10 D9

D8

D7

D6

D5

D4

D3

D2

D1

D0

Error Table

Not in use

Read Data

Selected Resp.

CMD

flag

Bit no.

1

st

Dword Description

D31

0: No module found 1: MCS-08IO at address [7] is active

Active MCS-08IO
modules

D30

0: No module found 1: MCS-08IO at address [6] is active

D29

0: No module found 1: MCS-08IO at address [5] is active

D28

0: No module found 1: MCS-08IO at address [4] is active

D27

0: No module found 1: MCS-08IO at address [3] is active

D26

0: No module found 1: MCS-08IO at address [2] is active

D25

0: No module found 1: MCS-08IO at address [1] is active

D24

0: No module found 1: MCS-08IO at address [0] is active

D23

0: No module found 1: MCS-08AD at address [7] is active

Active MCS-08AD
modules

D22

0: No module found 1: MCS-08AD at address [6] is active

D21

0: No module found 1: MCS-08AD at address [5] is active

D20

0: No module found 1: MCS-08AD at address [4] is active

D19

0: No module found 1: MCS-08AD at address [3] is active

D18

0: No module found 1: MCS-08AD at address [2] is active

D17

0: No module found 1: MCS-08AD at address [1] is active

D16

0: No module found 1: MCS-08AD at address [0] is active

D15
D14
D13
D12

Error
Codes

0000

No error found

Error Codes of
MCS-08Px

0001

System failure. Re-energize module. If happens
again, replace module.

0010

EEPROM failure. Re-energize module. If happens
again, replace module.

0011

Gateway module error. Re-energize module.
Check if gateway module is installed. If happens
again, replace module.

0100

No module found on N-bus. Install MCS-08AD or
MCS-08IO modules. Check N-bus connectors if
installed.

0101

A module was installed/removed. Re-address the
modules on the N-bus.

D11…D4

Not in use

D3
D2
D1

Read
Command
Response

010

All active MCS-08AD modules refer to

D16…D31

Read selected
response

001

Active MCS-

08IO modules refer to D16…D31

000

All active modules refer to D16…D31 (default)

D0

Toggles

The command is applied successfully

CMD flag


MCS-

08 AD

[0]*

2

nd

Dword

(R)

D31 D30 D29 D28 D27 D27 D25 D24 D23 D22 D21 D20 D19 D18 D17 D16
D15 D14 D13 D12 D11 D10 D9

D8

D7

D6

D5

D4

D3

D2

D1

D0

Indicated weight value will be shown in this Dword

3

st

Dword

(R)

D31 D30 D29 D28 D27 D27 D25 D24 D23 D22 D21 D20 D19 D18 D17 D16

Not In Use

D15 D14 D13 D12 D11 D10 D9

D8

D7

D6

D5

D4

D3

D2

D1

D0

Error Table Of

MCS-08AD Modul

Count

mo

de

Z

ero

range

Net

Mo

ti

on

Response of Read Selected

Data.

CMD

flag