beautypg.com

Mcs-08dp, Display module, Front view – Flintec MCS-08 User Manual

Page 35: Electrical connections, Isplay, Odule

background image

MCS-08 Technical Manual, Rev. 1.04 December 2012

Page 35 of 52

7. MCS-08DP

D

ISPLAY

M

ODULE

The MCS-08DP module is a display unit for the MCS-08 system. The weight/force or count data and stable,
zero, net information of one MCS-08AD module can be displayed. All installed MCS-08AD modules on the N-
Bus are indicated with their N-Bus address information. Two keys on the front panel are used for selecting the
A/D Converter module to display the weight or count data.

7.1. Front View

Active A/D Converter

Weight, force or count data

Pwr, Stable, Zero, Net indication

Module Selector Switch: select the

A/D Converter to display

Power Supply Terminal

Figure 7.1

– Front view

The meanings of these LEDs in operation are described below.

LED

Symbol

Name

Description

Active MCS-08AD module

Module is active

Currently displayed module

No module installed

Stable

Stable
Unstable

Centre of Zero

In the centre of zero range

( -0.25 e < w < 0.25 e )

Out of the centre of zero range

Net

Net

Net indication
Gros indication

Pwr

Power

Power indication
Displayed data is overflown to 6

th

or 7

th

digit

Table 7.1

– Status LEDs

7.2. Electrical Connections

Power Supply Connection

See chapter 4.2.1