Mcs-08dp, Display module, Front view – Flintec MCS-08 User Manual
Page 35: Electrical connections, Isplay, Odule
MCS-08 Technical Manual, Rev. 1.04 December 2012
Page 35 of 52
7. MCS-08DP
–
D
ISPLAY
M
ODULE
The MCS-08DP module is a display unit for the MCS-08 system. The weight/force or count data and stable,
zero, net information of one MCS-08AD module can be displayed. All installed MCS-08AD modules on the N-
Bus are indicated with their N-Bus address information. Two keys on the front panel are used for selecting the
A/D Converter module to display the weight or count data.
7.1. Front View
Active A/D Converter
Weight, force or count data
Pwr, Stable, Zero, Net indication
Module Selector Switch: select the
A/D Converter to display
Power Supply Terminal
Figure 7.1
– Front view
The meanings of these LEDs in operation are described below.
LED
Symbol
Name
Description
Active MCS-08AD module
Module is active
Currently displayed module
No module installed
Stable
Stable
Unstable
Centre of Zero
In the centre of zero range
( -0.25 e < w < 0.25 e )
Out of the centre of zero range
Net
Net
Net indication
Gros indication
Pwr
Power
Power indication
Displayed data is overflown to 6
th
or 7
th
digit
Table 7.1
– Status LEDs
7.2. Electrical Connections
Power Supply Connection
See chapter 4.2.1