10.3. N-Bus Addressing
MCS-08 modules communicate to each other over the internal N-bus. The MCS-08xx gateway module is the
master of the internal N-bus. All other MCS-08 modules are slaves and have to be addressed to the gateway
module. The N-bus addressing can be done by using the xFace PC software (refer to chapter 5.3) or via setup
switch (refer to chapter 5.8).
10.4. Profibus Setup
The Profibus setup is done by the xFace software. Connect the gateway module with your PC via the RS-232C
service port on the module as shown in figure 10.2. After connecting the xFace software with the gateway
module select the Gateway tab. The Gateway tab is shown in figure 10.3. It displays all gateway information
and Profibus settings.
Figure 10.3
– MCS-08PB gateway setup
You will see the Profibus setup in this tab.
Profibus Rack Address
The Profibus rack address range is 01 (default) to 126.
Displayed Gateway Information
External Bus: Profibus DP
Firmware Version: Revision number of the firmware
Firmware Date: Release date of the firmware
Hardware Version: Revision number of the main printed circuit board
Serial Number: The module‟s serial number
Gateway Status: Indicates the system OK status
Profibus DP Data Structure
Please refer to chapter 5.12