beautypg.com

Flintec DAS 72.1 User Manual

Page 52

background image

C.4.12 Commands Analogue Output 4 – 20 mA - AL, AH, AA

The following commands must be saved in EEPROM by command AS.

AA

Sets the source which will be used by analogue output

Possible selections for analogue output:

AA = 0

gross weight

AA = 1

net weight

AA = 2

Peak value

AA = 3

Average value

AA = 4

Hold value

AA = 5

Peak-to Peak value

AA = 6

Valley value

AA = 7

Hold value

AA = 8

analogue output OFF

Request / Set up analogue output:

Master ( PC / PLC ) sends

DAS 72.1 responds

Result

AA

¿

A+00001

set net

AA_0

¿

OK

set gross

Factory default: 2 [= analogue output OFF]

AH

Set the analogue high level

Request / Set up high level for analogue output 20 mA:

Master ( PC / PLC ) sends

DAS 72.1 responds

Result

AH

¿

H+10000

Request: 10 000 d @ 20 mA

AH_5000

¿

OK

Setting: 5 000 d @ 20 mA

Factory default: 10 000 [10 000 d = 20 mA]

AL

Set the analogue low level

Request / Set up low level for analogue output 4 mA:

Master ( PC / PLC ) sends

DAS 72.1 responds

Result

AL

¿

L+00000

Request: 00 000 d @ 4 mA

AL_00500

¿

OK

Setting: 500 d @ 4 mA

Factory default: 00 000 [0 d = 4 mA]

Page 52

Manual DAS 72.1