TR
Trigger
This command will start the measuring cycle in the same way as the hardware trigger input.
Master ( PC / PLC ) sends
DAS 72.1 responds
Result
TR
¿
OK
Trigger started
TL
Trigger Level
Set the trigger level for rising edge start of measurement. Permitted values are in the range 0 … 99 999.
Master ( PC / PLC ) sends
DAS 72.1 responds
Result
TL
¿
T+99999
Request: TL=99 999
TL_1000
¿
OK
Setting: TL=1 000
With regard to all the trigger commands (SD, TR, TE, TL), a check weighing will automatically restart when
the weight falls below or overshoots by 1000 d (increment), e.g. 100,0 g.
Factory default: 99 999
Page 32
Manual DAS 72.1
t
M
(g)
SD
Start Delay
MT
Measuring Time
Typical Checkweigher Signal
Trigger point
choose 1 of 3:
1. Light barrier or
2. TR command or
3. TL Trigger Level
The Timing Diagram for Check Weighing