COMMANDS SUMMARY

Manual DAS 72.1

Page 27

Command

Short

D

escription

Usage

P

arameter

Values

Typical

A

nswer

AA

Get/set

analog

action

A

nalog

action

0

through

8

A

+00000/OK/ERR

AD

Network

address

R

ead/modify

N

etwork

address

0

through

255

A:014/OK/ERR

AG

Absolute

gain

calibrate

(TAC

protected)

C

ailbrate

gain

using

absolute

sensitivity

in

mV/V

(without

dp)

+/-32000;

0

through

99999

G+2.0000/OK/ERR

AH

Get/set

analog

h

igh

A

nalog

calibration

point

2

0

m

A

(high)

-99999

through

9999

H+10000/OK/ERR

AIn

Action

input

n

Function

of

logic

input

1,

2

or

3

0

through

14

In:+00006

AL

Get/set

analog

low

Analog

calibration

point

4

mA

(low)

-99999

through

99999

L+00000/OK/ERR

An

Get/set

setpoint

n

action

S

etpoint

action

1

,

2

or

3

0

through

8

A

n:+00000/OK/ERR

AS

Save

analog

output

parameters

Save

AL,

A

H,

AA

to

EEPROM

n

one

O

K/ERR

AZ

Absolute

zero

calibrate

(TAC

protected)

C

albrate

zero

u

sing

absolute

zero

in

mV/V

(without

decimal

p

oint)

-32000

through

32000

Z+0.000/OK/ERR

BR

Baudrate

R

ead/modify

b

audrate

setting

9600

through

115200

B

9600

CE

Calibrate

enable

Open

legal

p

arameters

(CE

'TAC')

0

through

65535

E+00001/OK/ERR

CG

Calibrate

gain

(TAC

protected)

C

alibrate

gain

at

some

load

>>

zero

0

through

99999

G+20000/OK/ERR

CI

Calibrate

min

(TAC

p

rotected)

R

ead/modify

m

in

0

through

-99999

I+09000/OK/ERR

CL

Close

all

connections

Close

all

devices

(OP

XXX

implies

C

L)

none

none

CM

Calibrate

max

(TAC

p

rotected)

R

ead/modify

m

ax

0

through

99999

M+30000/OK/ERR

CS

Calibrate

save

(TAC

protected)

S

ave

C

M,

CZ

,

A

Z,

CG,

AG,

D

S,

DP,

Z

T

to

EEPROM

n

one

O

K/ER

CZ

Calibrate

zero

(TAC

protected)

C

alibrate

zero

-

n

o

load

on

platform

none

OK/ER

DP

Decimal

p

oint

(TAC

protected)

R

ead/modify

d

ecimal

p

oint

position

0

through

5

P

+00005/OK/ERR

DS

Display

step

size

(TAC

p

rotected)

R

ead/modify

the

display

step

size

1

,

2

.5,

10,

20,

50,

100,

200,

500

S+00001/OK/ERR

DX

Duplex

Select

half

(0)

or

full

(1)

duplex

0

oder

1

X+000/OK/ERR

FD

Factory

d

efault

(TAC

protected)

Load

factory

d

efaults

into

EEPROM

n

one

O

K/ER

FL

Filter

setting

Read/modify

filter

setting

0

through

8

F+00008/OK/ERR

FM

Filter

mode

Read/modify

filter

mode

setting

0

oder

1

M+00001/OK/ERR

GA

Get

A

verage

weight

Returns

the

current

average

value

none

A+00000

GG

Get

G

ross

value

R

eturns

the

g

ross

value

n

one

G

+01100

GH

Get

H

old

value

Returns

the

hold

value

n

one

H

+01000/OK/ERR

GM

Get

P

eak

value

(maximum)

Returns

the

peak

value

n

one

M

+00100

GN

Get

N

et

value

R

eturns

the

n

et

value

n

one

N

+00000

GO

Get

P

eak

to

Peak

value

R

eturns

the

P

eak

to

Peak

value

n

one

O

+01000/OK/ERR

GS

Get

sample

R

eturns

the

A

/D

value

n

one

S

+000000

GT

Get

T

are

value

Returns

the

tare

value

n

one

T

+00000

GV

Get

Valley

value

(minimum)

R

eturns

the

valley

value

none

V+01000/OK/ERR

GW

Get

long

W

eight

information

G

et

long

weight

information

n

one

W

+00100+01100010F

Hn

Get/set

setpoint

n

hysteresis

Setpoint

hysteresis

1,

2

or

3

-99999

through

99999

Hn:+00000/OK/ERR