beautypg.com

EVCO EVFTFT618N7U User Manual

Page 57

background image

EVCO S.p.A.

EVFTFT618 | Installer manual ver. 2.2 | Code 144FTFT618E224

Page

57

of

62

Analogue inputs:

3 inputs (cabinet probe, evaporator probe, condenser probe), can be set via

configuration parameter for PTC/NTC probes

1 digital input (humidity sensor).

PTC type analogue inputs (990 Ω @ 25°C, 77°F)

Type of sensor:

KTY 81-121.

Measurement field:

from

-50

to

150℃

(from -58 to 302°F).

Resolution:

1 °C (1 °F).

Protection:

none.

NTC type analogue inputs (10K Ω @ 25°C, 77°F)

Type of sensor:

ß3435.

Measurement field:

from

-40

to

105℃

(from -40 to 220 ℃).

Resolution:

1 °C (1 °F).

Protection:

none.

4-20 mA analogue input

Digital inputs:

4 inputs (door micro switch, high pressure, low pressure and compressor

circuit breaker protection), which can be set via configuration parameter due

to normally open contact/normally closed contact (potential-free contact, 5

VDC, 2 mA)

Digital inputs

Power:

none.

Protection:

none.

Displays:

320

x

240

pixel

(3.5 inch) colour TFT graphics display

Analogue outputs:

1 PWM output for management of the evaporator fan.