beautypg.com

EVCO EVFTFT618N7U User Manual

Page 40

background image

EVCO S.p.A.

EVFTFT618 | Installer manual ver. 2.2 | Code 144FTFT618E224

Page

40

of

62

rC5

0

10

°C

1

cooling neutral area value for the baking delay phase

rC6

-99

99

°C

2

pre-cooling set-point

Par.

Min.

Max.

Unit

Default

Heating regulator

rH0

1

15

°C

2

rH3, rH4, rH5 parameters differential

rH1

-99

rH2

°C

0

minimum set-point that can be set for the recovery,

proving, making delay and manual heating phases

rH2

rH2

99

°C

40

maximum set-point that can be set for the recovery,

proving, making delay and manual heating phases

rH3

0

10

°C

1

heating neutral area value for the block, storage and

manual cooling phases

rH4

0

10

°C

1

heating neutral area value for the recovery, proving and

manual heating phases

rH5

0

10

°C

1

heating neutral area value for the baking delay phase

rH6

1

600

sec

60

cycle time for switch-on of the heating elements in the

event of a heating request (see also rh7)

rH7

1

600

sec

45

heating elements switch-on time within the cycle time rH6

rr0

1

10

- - - -

4

number of regulation steps in the recovery phase

rr1

1

rr2

%

25

increase percentage 1st recovery step (with respect to

100% total)

rr2

rr1

rr3

%

50

increase percentage 2nd recovery step (with respect to

100% total)

rr3

rr2

rr4

%

75

increase percentage 3rd recovery step (with respect to

100% total)

rr4

rr3

100

%

100

increase percentage 4th recovery step (with respect to

100%)

rr5

rr4

rr6

%

- - - -

increase percentage 5th recovery step (with respect to

100%)

rr6

rr5

rr7

%

- - - -

increase percentage 6th recovery step (with respect to

100%)

rr7

rr6

rr8

%

- - - -

increase percentage 7th recovery step (with respect to

100%)

rr8

rr7

rr9

%

- - - -

increase percentage 8th recovery step (with respect to

100%)

rr9

rr8

rr10

%

- - - -

increase percentage 9th recovery step (with respect to

100%)

rr10

rr9

100

%

- - - -

increase percentage 10th recovery step (with respect to

100%)

rL0

1

10

- - - -

4

number of resistor regulation steps in the proving phase

rL1

1

rL2

%

25

increase percentage 1st proving step (with respect to

100%)